Calculator
Under-cabinet lighting calculator
Enter the length of counter you want to light, how demanding the work is and how dark the counter is. You get lumens per foot, a total, and roughly how many strips or bars that makes. It updates as you type and nothing leaves your device.
2,760 lumens in total
Worked example (shown when scripts are off): 8 ft of regular prep counter with a medium color needs about 345 lumens per foot, so about 2,760 lumens. In 24 inch bars that is four, around 690 lumens each.
A starting point
Published numbers vary a lot between sources. Use a dimmable product, then adjust by eye after dark.
How the calculator works
Lumens measure the light a product gives out, and the number is on the box. Under-cabinet guidance is usually given per linear foot of counter. The calculator starts from 200 lumens per foot for light use, 300 for regular cooking and 400 for detailed work. It multiplies by 1 for a light counter, 1.15 for a medium one and 1.3 for a dark one, because dark surfaces absorb light. The result is then kept between 125 and 500 lumens per foot and rounded to the nearest 5. Total lumens are lumens per foot times the length of the run. The fixture count is the run length divided by the fixture length, rounded up.
The 125 floor is the minimum an ENERGY STAR-type specification asks for in kitchen under-cabinet products. The 200 to 500 range is the usual practical range given in lighting guides. The base values and the counter multipliers are our own planning choices within that range, not a standard.
Worked example
An 8 foot run of regular prep counter in a medium color gives 300 times 1.15, which is 345 lumens per foot. Over 8 feet that is 2,760 lumens. With 24 inch bars, 96 inches divided by 24 is 4 bars, each giving about 690 lumens. Wattage is not used, since the same watts give very different light from different products.
Color and glare
Choose a color temperature close to your ceiling lights, commonly 2700K to 3500K in a kitchen, so the room looks consistent. Look for a color rendering index (CRI) of 90 or higher, which makes food and wood look natural. Shiny counters reflect a bare strip as a bright line, so a lensed or diffused product mounted near the front edge of the cabinet reduces glare.
Renter and safety notes
Plug-in and battery-powered strips need no wiring, which suits rentals; use removable mounts and keep the original surface clean. Run cords where they cannot touch a hot cooktop, and keep them away from the sink. Hardwired lights and any new circuit are electrical work for a licensed electrician, and local code applies. Never work on a live circuit.
Limits
This is a planning aid. Counter depth, cabinet height, how far the light sits from the front and the beam angle all change what reaches the counter, and the calculator does not model them. Very long runs or unusual cabinets need more care. It is general information, not professional lighting design.
Where this comes from
We checked the US Department of Energy under-cabinet lighting brief, which describes ENERGY STAR kitchen criteria including the 125 lumens per linear foot minimum, and several trade and lighting guides that give about 200 to 500 lumens per foot for kitchen counters. We did not read the original standards, so the range comes from secondary sources, and sources do disagree.